Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add filters








Language
Year range
1.
Chinese Journal of Orthopaedic Trauma ; (12): 158-162, 2016.
Article in Chinese | WPRIM | ID: wpr-489209

ABSTRACT

Objective To compare biomechanical effects of augmentative plating assisted by different types and numbers of intramedullary nails in the treatment of nonunion of femoral shaft fracture after intramedullary nailing.Methods Twenty-five specimens of synthetic femur were randomly divided into an experimental group (20 bones) and a control group (5 bones).All the bones were made into models of nonunion of femoral shaft fracture after intramedullary nailing.The control group was subjected to no augmentative plating.The experimental group was further divided into 4 subgroups (n =5) which were subjected to fixation respectively by:a 7-hole plate with 3 bicortical screws on each side,a 7-hole plate with 3 unicortical screws on each side,a 5-hole plate with 2 bicortical screws on each side,and a 5-hole plate with 2 unicortical screws on each side.The torque values of all the subgroups were measured and compared when the models were subjected to torsional angles of 5°,10°,15°,20° and 25°.Results The anti-torsional strengths at torsional angles of 5°,10°,15°,20° and 25° in the 4 experimental groups were all significantly greater than in the control group(P < 0.05).At a torsion angle of 25°,the mean torque value in the 3-bicortical-screw group (46.51 ±6.66 nm) was significantly greater than in the 2-bicortical-screw group (39.03 ±8.52 nm) (P <0.05).At torsion angles of 5°,10°and 25°,the mean torque values in the 3-unicortical-screw group (13.48±1.68 nm,23.29±3.72 nm and 48.19±5.34 nm,respectively) were significantly greater than in the 3-unicortical-screw group (9.56 ± 3.62 nm,16.99 ± 5.49 nm and 38.69 ± 6.56 nm,respectively) (P < 0.05).At torsion angles of 20° and 25°,the mean torque values in the 3-unicortical-screw group (39.15 ± 5.07 nm and 48.19 ± 5.34 nm) were significantly greater than in the 2-bicortical-screwgroup (32.50 ± 5.65 nm and 39.03 ± 8.52 nm) (P <0.05).Conclnsions The anti-torsional strength of fixation by 3 screws on each side is significantly greater than by 2 screws on each side.When the number of screws is the same,there is no significant difference between fixation by unicortical locking screws and that by bicortical conventional screws.Augmentative plating with 3 unicortical screws or 3 bicortical conventional screws on each side is recommended for treatment of nonunion of femoral shaft fracture after intramedullary nailing.

2.
Chinese Journal of Tissue Engineering Research ; (53): 5735-5740, 2015.
Article in Chinese | WPRIM | ID: wpr-481790

ABSTRACT

BACKGROUND:Although the therapeutic effect of total knee arthroplasty for severe gonarthritis is reliable, deep vein thrombosis also occurred in many patients. Therefore, deep vein thrombosis has been a major reason for unexpected death after total knee arthroplasty. OBJECTIVE:To study the incidence of deep vein thrombosis after total knee arthroplasty with general and epidural anesthesia. METHODS:We searched“PubMed”,“Medline”,“Elsevier”,“Embase”, Cochrane library,“Wanfang”,“China National Knowledge Infrastructure”for papers published from January 2000 to March 2015. The mesh words were“total knee arthroplasty”,“TKA”,“thrombosis”,“DVT”,“randomized control ed trial”,“RCT”for studies concerning deep vein thrombosis after total knee arthroplasty with different anesthetic methods. The double blind method was used for data extraction and assessment of literature quality. Revman5.3 software was utilized to analyze the extracted data using meta-analysis. RESULTS AND CONCLUSION:There were 8 studies including 885 patients. The heterogeneity of the included studies was very low (I2=0, P=0.72). The combined OR was 0.25 (95%confidence interval:0.18, 1.35), indicating that continuous epidural anesthesia in total knee arthroplasty could apparently reduce the possible formation of postoperative deep vein thrombosis. Because of lack of the changes in coagulation factors under general anesthesia and epidural anesthesia, the mechanism underlying epidural anesthesia to reduce the incidence of deep vein thrombosis deserves further investigations. Among patients with deep vein thrombosis, continuous epidural anesthesia could diminish the possible formation of deep vein thrombosis. Thus, epidural anesthesia should be used firstly for knee replacement in patients with high risk of deep vein thrombosis.

3.
Chinese Journal of Rehabilitation Theory and Practice ; (12): 276-277, 2003.
Article in Chinese | WPRIM | ID: wpr-980441

ABSTRACT

@#目的探索脑瘫患儿早期发现、早期干预的工作模式。方法临床、保健、康复相结合 ,采用产前检查、孕妇学校、产时儿科医生进产房、新生儿行为神经评定测定、高危儿抚触训练室、婴儿期儿童保健监测、各街道防治站常规体检筛查转诊等多种形式结合早期发现并干预脑瘫高危儿。结果此工作模式较模式前显著提高了脑瘫的早期诊断率及康复疗效。结论临床、保健、康复相结合的方式整合了医疗资源,起到了促进脑瘫早发现、早诊断、早治疗的作用 ,值得推广。

SELECTION OF CITATIONS
SEARCH DETAIL